LX-19 Series Limit Switch
Operating speed:0.5mm~0.5m/s
Operating frequency:Mechanical: 120 operations/minute
Electrical: 30 operations/minute
Contact resistance:50mΩ max.(Initial value)
Insulation resistance:100mΩ min.(at DC500V)
Conventional thermal current:5A
Electric Parameter:AC380V/0.8A DC220V/0.1A
Dielectric strength:1890VAC, 50/60Hz 1min between terminals of the same polarity
2500VAC, 50/60Hz 1min between each terminal and non-current-carrying metal parts
2500VAC, 50/60Hz 1min between current-carrying metal parts and ground
Vibration resistance:Malfunction: 10Hz~55Hz, 1.5mm double amplitude
Shock resistance:Destruction: 1000m/S² Malfunction: 300m/S²
Ambient temperature:Ambient operation temperature: -5℃~+60℃ with no icing
Ambient humidity:Ambient operation humidity: 90% max.
Life expectancy :Mechanical: 6,000,000 operations min.
Electrical: 300 000 operations min.
Degree of protection:IP52 -
LX-D4C Waterproof Series Limit switch
Operating speed:1mm~1m/s
Operating frequency:Mechanical: 120 operations/minute
Electrical: 20 operations/minute
Contact resistance:200mΩ max.(Initial value with 3m cable)
Insulation resistance:100mΩ min.(at DC500V)
Conventional thermal current:5A
Electric parameter:AC250V/1A DC220V/0.3A
Dielectric strength:1890VAC, 50/60Hz 1min between terminals of the same polarity
2500VAC, 50/60Hz 1min between each terminal and non-current-carrying metal parts
2500VAC, 50/60Hz 1min between current-carrying metal parts and ground
Vibration resistance:Malfunction: 10Hz~55Hz, 1.5mm double amplitude
Shock resistance:Destruction: 500m/S² Malfunction: 200m/S²
Ambient temperature:-10℃~+70℃ with no icing
Ambient humidity:90% max.
Life expectancy:Mechanical: 10,000,000 operations min.
Electrical: 100 000 operations min.
Degree of protection:IP67 -
LX-K1 Series Limit Switch
Operating speed:0.5mm~0.5m/s
Operating frequency:Mechanical: 120 operations/minute
Electrical: 30 operations/minute
Contact resistance:50mΩ max.(Initial value)
Insulation resistance:100mΩ min.(at DC500V)
Conventional thermal current:5A
Electric Parameter:AC380V/0.8A DC220V/0.1A
Dielectric strength:1890VAC, 50/60Hz 1min between terminals of the same polarity
2500VAC, 50/60Hz 1min between each terminal and non-current-carrying metal parts
2500VAC, 50/60Hz 1min between current-carrying metal parts and ground
Vibration resistance:Malfunction: 10Hz~55Hz, 1.5mm double amplitude
Shock resistance:Destruction: 1000m/S² Malfunction: 300m/S²
Ambient temperature:Ambient operation temperature: -5℃~+60℃ with no icing
Ambient humidity:Ambient operation humidity: 90% max.
Life expectancy:Mechanical: 6,000,000 operations min.
Electrical: 300 000 operations min.
Degree of protection:IP52 -
LX-K3 Series Limit Switch
Operating speed:0.5mm~0.5m/s
Operating frequency:Mechanical: 120 operations/minute
Electrical: 30 operations/minute
Contact resistance:50mΩ max.(Initial value)
Insulation resistance:100mΩ min.(at DC500V)
Conventional thermal current:5A
Electric Parameter:AC380V/0.8A DC220V/0.1A
Dielectric strength:1890VAC, 50/60Hz 1min between terminals of the same polarity
2500VAC, 50/60Hz 1min between each terminal and noN-current-carrying metal parts
2500VAC, 50/60Hz 1min between current-carrying metal parts and ground
Vibration resistance:Malfunction: 10Hz~55Hz, 1.5mm double amplitude
Shock resistance:Destruction: 1000m/S² Malfunction: 300m/S²
Ambient temperature:Ambient operation temperature: -5℃~+60℃ with no icing
Ambient humidity:Ambient operation humidity: 90% max.
Life expectancy:Mechanical: 6,000,000 operations min.
Electrical: 300 000 operations min.
Degree of protection:IP52 -
LX-ME8000 Series Limit switch
Operating speed:0.5mm~50cm/sec
Operating frequency:Mechanical: 120 operations/minute
Electrical: 30 operations/minute
Contact resistance:25mΩ max.(Initial value)
Insulation resistance:100mΩ min.(at DC500V)
Dielectric strength:1000VAC, 50/60Hz 1min between terminals of the same polarity
1500VAC, 50/60Hz 1min between each terminal and no-current-carrying metal parts
1500VAC, 50/60Hz 1min between current-carrying metal parts and ground
Vibration resistance:Malfunction: 10Hz~55Hz, 1.5mm double amplitude
Shock resistance:Destruction: 1000m/S² Malfunction: 300m/S²
Ambient temperature:-5℃~+65℃ with no icing
Ambient humidity:90% max.
Life expectancy :Mechanical: 20,000,000 operations min.
Electrical: 300 000 operations min.
Degree of protection:IP65 -
LX-P1 Series Limit Switch
Operating speed:0.5mm~0.5m/s
Operating frequency:Mechanical: 120 operations/minute
Electrical: 30 operations/minute
Contact resistance:50mΩ max.(Initial value)
Insulation resistance:100mΩ min.(at DC500V)
Conventional thermal current:5A
Electric Parameter:AC380V/0.8A DC220V/0.1A
Dielectric strength:1890VAC, 50/60Hz 1min between terminals of the same polarity
2500VAC, 50/60Hz 1min between each terminal and non-current-carrying metal parts
2500VAC, 50/60Hz 1min between current-carrying metal parts and ground
Vibration resistance:Malfunction: 10Hz~55Hz, 1.5mm double amplitude
Shock resistance:Destruction: 1000m/S² Malfunction: 300m/S²
Ambient temperature:Ambient operation temperature: -5℃~+60℃ with no icing
Ambient humidity:Ambient operation humidity: 90% max.
Life expectancy :Mechanical: 6,000,000 operations min.
Electrical: 300 000 operations min.
Degree of protection:IP65 -
LX-WL Series Limit Switch
Operating speed:0.5mm~0.5m/s
Operating frequency:Mechanical: 120 operations/minute
Electrical: 30 operations/minute
Contact resistance:20mΩ max.(Initial value)
Insulation resistance:100mΩ min.(at DC500V)
Conventional thermal current:10A
Electric Parameter:AC220V/1.5A DC220V/0.3A
Dielectric strength:1890VAC, 50/60Hz 1min between terminals of the same polarity
2500VAC, 50/60Hz 1min between each terminal and non-current-carrying metal parts
2500VAC, 50/60Hz 1min between current-carrying metal parts and ground
Vibration resistance:Malfunction: 10Hz~55Hz, 1.5mm double amplitude
Shock resistance:Destruction: 1000m/S² Malfunction: 300m/S²
Ambient temperature:Ambient operation temperature: -5℃~+80℃ with no icing
Ambient humidity:Ambient operation humidity: 90% max.
Life expectancy:Mechanical: 15,000,000 operations min.
Electrical: 750 000 operations min.
Degree of protection:IP65 -
LX-Z1 Series Limit Switch
Operating speed:5mm~0.5m/s
Operating frequency:Mechanical: 120 operations/minute
Electrical: 20 operations/minute
Contact resistance:50mΩ max.(Initial value)
Insulation resistance:100mΩ min.(at DC500V)
Conventional thermal current:5A
Electric Parameter:AC220V/0.7A DC220V/0.07A
Dielectric strength:1890VAC, 50/60Hz 1min between terminals of the same polarity
2500VAC, 50/60Hz 1min between each terminal and non-current-carrying metal parts
2500VAC, 50/60Hz 1min between current-carrying metal parts and ground
Vibration resistance:Malfunction: 10Hz~55Hz, 1.5mm double amplitude
Shock resistance:Destruction: 500m/S² Malfunction: 200m/S²
Ambient temperature:Ambient operation temperature: -5℃~+85℃ with no icing
Ambient humidity:Ambient operation humidity: 90% max.
Life expectancy :Mechanical: 5,000,000 operations min.
Electrical: 100 000 operations min.
Degree of protection:IP66 -
LX-HL Series Limit Switch
Operating speed:0.5mm~0.5m/s
Operating frequency:Mechanical: 120 operations/minute
Electrical: 30 operations/minute
Contact resistance:25mΩ max.(Initial value)
Insulation resistance:100mΩ min.(at DC500V)
Conventional thermal current:5A
Electric Parameter:AC380V, AC220V/1A DC220V/0.3A
Dielectric strength:1890VAC, 50/60Hz 1min between terminals of the same polarity
2500VAC, 50/60Hz 1min between each terminal and non-current-carrying metal parts
2500VAC, 50/60Hz 1min between current-carrying metal parts and ground
Vibration resistance:Malfunction: 10Hz~55Hz, 1.5mm double amplitude
Shock resistance:Destruction: 1000m/S² Malfunction: 300m/S²
Ambient temperature:Ambient operation temperature: -5℃~+60℃ with no icing
Ambient humidity:Ambient operation humidity: 90% max.
Life expectancy :Mechanical: 5,000,000 operations min.
Electrical: 300 000 operations min.
Degree of protection:IP65
[Page:1 / 1][10 / Page][Total:9] << < 1 > >>